CENTRIA Profiled Series panels are available in a wide variety of assemblies with insulation and liners tested to achieve superior thermal performance. The following chart illustrates thermal performance of various assemblies as conducted by an independent laboratory in accordance with ASTM C1363.

Panel

U-value
w/ films

R-value
w/ films

FIELD-ASSEMBLED SYSTEMS

 

 

L2 liner w/ 2-inch 1.65# insulation , 1/2-inch hat-shaped subgirts

0.11

9.07

L2 liner w/ 2-inch 1.65# insulation + 1-1/2-inch 1.65# insulation nested in 1-1/2-inch zee-shaped subgirts

0.068

14.77

L2-2 liner w/ 3-inch 1.65# insulation, 1/2-inch hat-shaped subgirts

0.076

13.12

L2-2 liner w/ 3-inch 1.65# insulation + 1-1/2-inch 1.65# insulation nested in 1-1/2-inch zee-shaped subgirts

0.056

17.99

L2-3 liner w/ 4-inch 1.65# insulation, 1/2-inch hat-shaped subgirts

0.067

14.96

L2-3 liner w/ 4-inch 1.65# insulation + 1-1/2-inch 1.65# insulation nested in 1-1/2-inch zee-shaped subgirts

0.051

19.6